DL719
General Information
- Maximum possible measurement channels and inputs:
- 6 analog measurement channels
- 4 digital counter inputs
- 2 digital alarm/status inputs
- M-Bus (or mini="LowPower") or Modbus interface
- Sensors (e.g):
- Level, pressure, temperature, humidity
- pH value, conductivity, chemical parameters
- Precipitation, flow and status
- Memory capacity: ≥ 2,040,000 values
- Serial-/USB interface for PC
- Battery life: up to 10 years with daily measured value transmission (LTE)
- Protection rating: IP65
Options
- Built-in LTE modem
- Transmission of measured values and alarm notifications to:
- Control rooms and internet servers
- Fax machines
- Mobile or landline phones
- Antennas:
- Rod antenna (direct or via cable)
- Directional antenna
- Flush-mounted antenna …
- Power supply depending on model:
- Battery pack (alkaline)
- External via solar panel and buffer battery
- External via 12 VDC, 24 VDC, 110 VAC, 230 VAC and buffer battery
- Connection sockets: RD24 for measuring cables and power supply
Specifications
- Waterproof, rugged plastic housing (IP65)
- Up to 6 analog measurement channels for sensors (resolution: 0.025 %)
- Adjustable measuring interval from 32 Hz to 30 days
- Switched sensor supply (3 V ±5 %, max. 10 mA load)
- Measurement ranges:
Voltage: | 0–1 V and/or “LowPower” | ||
Current: | 0–±20 mA, 4–20 mA | ||
Event: | e.g. reed contact, up to 1 event per second | ||
Digital: | Low < 10 kΩ, High > 200 kΩ | ||
Frequency: | 0.01 Hz to 10 Hz (optional up to 2 kHz) |
- Storage capacity: 4 GB to 32 GB (approx. 2,040,000 to 16,768,000 values)
- External power supply:
- Via solar panel with rechargeable battery
- Or via power supply with internal buffer battery
- Typical power reserve: approx. 2 months (rechargeable battery) or 12 months (buffer battery)
- Battery power supply:
- With adjustable alarm
- Replaceable in the field
- Display of battery voltage and remaining capacity during operation
- Dimensions: 235 mm × 165 mm × 110 mm (L × W × H)
- Weight: approx. 3,800 g (battery version)
Operating time
Operating time without battery replacement under standard conditions:
|
| ||||
---|---|---|---|---|---|
1 minute | 5 minutes | 15 minutes | 60 minutes | ||
every 15 minutes | 12 months | 12 months | 12 months | 12 months | |
hourly | 1.5 years | 1.5 years | 1.5 years | 1.5 years | |
every 6 hours | 3 years | 3 years | 3 years | 3 years | |
daily | 4 years | 4 years | 4 years | 4 years |
*The operating time is reduced when using the optional M-Bus or Modbus – depending on the measuring interval
Accessories
- Battery DL09 Standard Lithium
- Battery DL09 2 pieces
- Battery DL09 Alkaline
- Battery DL09 Accumulator
- Configuration cable "serial"
- Configuration cable "USB"
- Software DLBA II
- Software IDA II
- Antennas
- Measuring cables & Adapters
- Mounting bracket
- Mounting unit for level borehole
- Level probe
- Conductivity sensor
- pH-probe
- Pressure sensor
- Rain gauge
- Temperature sensor
- Air temperature sensor
- Air pressure sensor
- Humidity sensor
- Wind speed & direction