Pressure Sensor
General Information
- Pressure Sensor for drinking water, waste water and air pressure
- No moving parts, therefore low maintenance
- Compatible all GERO data loggers
- Housing and membrane made of corrosion-resistant stainless steel
- High measurement accuracy: ± 0.1 %
- Available for absolute or relative pressure from 16 mbar to 250 bar
- Options:
- Quick-release coupling
- Venting valve
- Selectable Plug type and cable length
- Adapter for underground hydrants
Specifications
Measuring ranges: | 16, 25, 60, 100, 160, 250, 600 mbar 1.0, 1.6, 2.5, 6.0 bar 10, 16, 25, 60, 100, 160, 250 bar | (–M0016 … –M0600) (–M1.0 … –M6.0) (–M10 … –M250) | ||
Total error: | ≤ 0.50 % of full scale ≤ 0.25 % of full scale ≤ 0.10 % of full scale | (–T05) (–T025) (–T01) | ||
Response time: | < 3 ms | |||
Overload limit: | 3 × full scale | |||
Operating temperature: | 0 to 50 °C | |||
Output signal: | 0–50 mV 0–5 V 4–20 mA | (–SMV) (–SV) (–SMA) | ||
Supply voltage: | 10 V stabilized 10–30 V 10–30 V | (with 50 mV output, –SMV) (with 5 V output, –SV) (with 4–20 mA output, –SMA) | ||
Connection: | Fixed cable Plug, Binder 5-pin Plug, M12 4-pin | (–CF) (–CL) (–CM12) | ||
Protection rating: | IP68 (with fixed cable up to 160 m immersion depth) | |||
Cable: | PVC-coated polyurethane cable with Kevlar strain relief and pressure compensation tube Length according to customer specification Suitable for use up to 250 m without additional strain relief | (–Lxxxx in mm) | ||
Options: | 90° quick coupling Vent valve Connection set ¼″, ⅜″, ½″, ¾″ Adapter for underground hydrants 230 V power supply for DIN rail mounting | (–SVK) (–EV) (–ANS) (–AUH) (–HMP) |